Troubleshooting
7-3
MARKING
GEN
TEST
PATTERN
GEN
TEST
PATTERN
COMP
TRANSMITTER
RECEIVER
IDLE
SEQUENCE
DTE
TX
RX
LOCAL DAP
Figure 7-1. Self-Error Test
Local-Error Test
The Local-Error Test checks the interface circuitry for faults. To perform the test, you
must disconnect the cable connected to the 8-pin modular jack labeled DED on the
DAP's rear panel and replace it with a looping cable. To make this connection, connect
cable connector Pin 8 (Receive Ring) to DAP connector Pin 1 (Transmit Ring) and cable
connector Pin 7 (Receive Tip) to DAP connector Pin 2 (Transmit Tip). This cable is not
supplied by Milgo.
The Local-Error Test can only be activated manually through the DAP's front panel. It
can not be activated from CMS.
When this test is activated, the DAP generates a test pattern through the DDS interface
which is looped back via the looping cable. (See Figure 7-2.) A test pattern comparator
checks the pattern for errors. During the test, the DAP's clocking is automatically set to
internal. The Excalibur Multirate DAP lets you program how long (1 - 999 seconds or
continuous) you wish this test to run. The recommended length is 60 seconds. Errors
occurring during this test generally indicate that the problem lies with the interface
circuitry.
Note: The Local-Error Test is a full bandwidth test.
TX
RX
LOCAL DAP
TEST
PATTERN
GEN
TEST
PATTERN
COMP
EXTERNAL
LOOPBACK
DTE
LINES
Figure 7-2. Local-Error Test (Interface Circuitry)