Excalibur Multirate DAP Installation and Operation
5-60
2. Press the button beneath Store.
1
234
Escape
Top
L
S y s t e m C o n f i g u r a t i o n
S t o r e S w a p F c t r y R e s e t
<
>
3. Press the 1 button to store the current parameter settings.
1
234
Escape
Top
L
S t o r e S y s t e m C o n f i g T o
C f g - 2
<
>
Once you have stored a configuration, you can then swap it with the current parameter
configuration. To do so, enter the System submenu and press the button beneath Swap.
Then press the 1 button. The DAP then powers down and powers up with the new
parameter configuration in place. (Data is interrupted while the unit is reset and
reinitialized.)
Note: It is recommended that you do not perform this function from the RCP.
If you wish to replace the current parameter configuration with the factory default
settings, enter the System submenu and press the button beneath Fctry. Then press the
button beneath Ok. (Data is interrupted while the unit is reset and reinitialized.)
If you wish to initiate a soft unit reboot, enter the System submenu and press the button
beneath Reset. Then press the button beneath Ok. (Data is interrupted while the unit is
reset and reinitialized.)